Rated capacities .......................... |
300 kgf, 600 kgf, 1.2 tf |
Rated output .................................. |
1.5 mV/V+15%/-0%(1 mV/V+15%/-0%)* |
Maximum deadweight ................. |
20% (50%) of rated capacity |
Maximum safe overload .............. |
200% of rated capacity |
Combined error ............................ |
±0.015% of rated output |
Creep .............................................. |
±0.05% of rated output/hour |
Zero balance ................................. |
25±10% of rated output |
Compensated |
temperature range ........................ |
-10 °C to +40 °C/+14 °F to +104 °F |
Recommended |
excitation voltage ........................... |
12 V |
Maximum |
excitation voltage ........................... |
15 V |
Input terminal resistance .............. |
Approximately 200 Ω |
Output terminal resistance ......... |
175 Ω ± 1 Ω |
Insulation resistance ................... |
Greater then 500 MΩ at DC50 V |
Temperature effect |
Zero ................................................. |
0.004% of rated output/°C |
Span ................................................ |
0.0014% of rated output/°C Typ. |
Platform size .................................. |
0.9 × MAX. 2.0 m (35 × MAX. 79 inches)
1.2 × MAX. 2.0 m(47 × MAX. 79 inches) |
Weight ............................................ |
50 kg (30 kg) 110 Ibs (66 lbs) |
Cable length ................................. |
2 m/79 inches *( ) = Specifications for LC4212-K300 |