LCB25 (Aluminum)
Compact Single Point Load Cell
LCB25
Capacity Model No.
500 gf LCB25-G500
1 kgf LCB25-K001
2 kgf LCB25-K002
3 kgf LCB25-K003
Download 3D CAD
PDFBrochure (PDF 289KB)
PDFManual (PDF 459KB)
Please send your inquiry here
Features
High resolution and super compact design, perfect for limited spaces like multi-row filling machines.
Moisture proof
Pre-adjusted corner load for easy scale creation.
Supports both tension and compression.
Specifications
LCB25-G500 LCB25-K001/K002/K003
Rated output 1 mV/V±10% 2 mV/V±10%
Safe load limit 300% of R.C. 150% of R.C.
Ultimate safe overload 400% of R.C. 200% of R.C.
Combined error 0.02% of R.O.
Zero balance ±10% of R.O.
Recommended excitation voltage DC5~25 V
Max. excitation voltage DC25 V
Maximum Platform size 200 × 200 mm
Input terminal resistance 1.17 kΩ ±100 Ω
Output terminal resistance 1 kΩ ±10 Ω
Insulation resistance 2,000 MΩ or greater /DC 50V
Compensated temp. range -10 ℃~40 ℃
Temp. effect on Zero balance ±0.023 % of R.O./10 ℃
Temp. effect on span ±0.014 % of Load/10 ℃ Typ.
Cable Dia. And length φ 3.5, 4 core shielded cable x 0.4m
A shielded cable is connected to the load cell body
Dust/Water proof IP65
Material Aluminum
Net Weight 40 g approx.