Safe load limit |
150% of R.C. |
Combined error |
0.5% of R.O. |
Supply voltage |
DC5 V ± 0.25 V less than 16mA |
Load resistance |
More than 5 kΩ |
Output voltage *1 |
1 V to 4 V |
Zero voltage |
1 V ± 0.04 V |
Span voltage |
2 V ± 0.01 V (1 V to 3 V) |
Insulation resistance |
500 MΩ / DC50 V between signal wires and load cell |
Compensated temperature range |
0 °C to 70 °C |
Permissible temperature range |
-10 °C to 80 °C |
Temperature effect |
Zero |
0.6% of R.O. / 10 °C Typ. |
Span |
0.6% of Load / 10 °C Typ. |
Frequency characteristics |
100Hz (–3dB) |
Cable diameter/length |
From load cell to amplifier |
φ2 mm / 2 m |
From amplifier |
φ6 mm / 0.5 m |
Dustproof/Waterproof |
Load cell IP64 |
Standard attachment holder |
1 piece |
Standard amplifier case holder |
1 set |