Product
Weighing
| LC-4101 (Aluminum) | |||||||||||||||
| For small capacity weighing applications,single point compact load cells | |||||||||||||||
|
|||||||||||||||
| Features | |||||||||||||||
|
|
|||||||||||||||
| Specifications | |||||||||||||||
|
Rated capacities....................... 600gf, 1.5kgf, 3kgf, 0kgf,15kgf Rated output ...............................1mV/V+15/-0% Maximum deadweight ..............80% of rated capacity Maximum safe overload ..........300% of rated capacity Combined error ........................±0.015% of rated output Creep ..........................................±0.05% of rated output/hour Zero balance .............................20±5% of rated output Compensated temperature range.................. -10°C~+40°C/+14°F~+104°F Recommended excitation voltage .....................12V Maximum excitation voltage .....................15V Input terminal resistance....... Approximately 400Ω Output terminal resistance ...350Ω±5Ω Insulation resistance .............Greater than 5000MΩ at DC50V Temperature effect Zero ...........................................0.004% of rated output/°C Span ..........................................0.0014% of rated output/ Type. Platform size ...........................300×300mm/11.8×11.8 inches Cable length ............................1.5m / 59 inches |
|||||||||||||||
|