| LCB04 (Aluminum) |
| Adjusted for 4 corners, useful for platform scale, single point compact load cells |
 |
 |
| Capacity |
Model No. |
CAD File |
| LCB04M Series |
| 60kgf |
LCB04K060M |
Download |
| 100kgf |
LCB04K100M |
| LCB04L Series |
| 150kgf |
LCB04K150L |
Download |
| 250kgf |
LCB04K250L |
|
|
| Features |
Ultra Compact Design -Just 15cm in length
Calibrated for 4 corner loads
Moisture Proof
4 Models to Choose from |
 |
| Specifications |
| Rated capacities |
60kgf, 100kgf, 150kgf, 250kgf |
| Rated output |
2mV/V±10% |
| Safe overload |
150% of R.C. |
| Maximum overload |
200% of R.C. |
| Combined error |
0.02% of R.O. |
| Repeatability |
0.02% of R.O. |
| Creep |
0.02% of R.O.(30min) |
| Maximum excitation voltage |
DC15V |
| Zero balance |
±5% of R.O. |
| Input terminal resistance |
420±30Ω |
| Output terminal resistance |
350±5Ω |
| Insulation resistance |
2000MΩ(B/E DC50V) |
| Operating temperature |
-10°C to 40°C |
| Temperature effect |
Zero |
0.023% of R.O./10°C |
| Span |
0.014% of R.O./l 0°C |
| Cable diameter/Length |
o 3.5/1.5m |
| Maximum platform size |
400mm×400mm |
|
|