LCM17 Series |
Flameproof enclosure stainless steel beam load cells for platform, tank or hopper scales |
 |
 |
Capacity |
Model No. |
CAD File |
102 kg (1 kN) |
LCM17K100E |
Download |
204 kg (2 kN) |
LCM17K200E |
306 kg (3 kN) |
LCM17K300E |
510 kg (5 kN) |
LCM17K500E |
1.02 t (10 kN) |
LCM17T001E |
2.04 t (20 kN) |
LCM17T002E |
Download |
|
|
|
Features |
Suitable for use in harsh environments where flammable hazardous substances are handled and corrosion resistance is required.
Suitable for platform or tank scales.
For both tension and compression applications. |
 |
Specifications |
Rated output |
1.0 mV / V±0.1% (For 1 kN only, 0.5 mV / V±0.1%) |
Safe load limit |
150% of R.C. |
Combined error |
0.03% of R.O. |
Recommended excitation voltage |
DC5 to 12 V |
Maximum excitation voltage |
DC15 V |
Zero balance |
±2% of R.O. |
Input terminal resistance |
390 ± 30 Ω |
Output terminal resistance |
350 ± 5 Ω |
Insulation resistance |
5000 MΩ or higher / DC50 V |
Compensated temperature range |
-10 °C to 40 °C |
Temperature effect |
Zero |
0.028% of R.O. / 10 °C |
Span |
0.011% of Load / 10 °C Typ. |
Insulation resistance |
5000 MΩ at DC50 V |
Cable diameter / length |
φ7 / 5 m |
Dust & Waterproof |
IP54 |
Flameproof type |
Exd II BT4 |
|
|